(6-2) Setting procedure of the camera using demonstration display software
<Setting procedure using "GEVPlayer">
This camera supports GenICam API established by EMVA(European Machine Vision association).
Display software "GEVPlayer" included in the attached SDK "eBUS-PureGEV Package" is GenICam API-compatible.
And it can change most of set contents (e.g. Gain setting, Shutter speed etc.) by directly specifying parameter value for
each prescribed feature from this software.
→ In this case, there is no need to use serial communication software such as "FCTool".
<Setting procedure using serial communication command>
It can execute camera setting with "GenICam API" by using demonstration display software "Coyote" in the attached SDK
"eBUS-Vision Package" and the serial communication software (such as "FCTool") .
→ Refer to "7.Serial communication command" for the detail about setting procedure using serial communication command.
(6-3) Example of camera setting with
It can directly confirm and change the setting parameters of the camera without the serial communication software (such
as "FCTool") from the application software by using GenICam API.
Following examples show the parameter setting procedure of the camera using the Image display software "GEVPlayer"
included in the attached SDK "eBUS-PureGEV Package".
Various examples of the way to change settings using the Control dialogue "GEV Device Control" are provided.
(Example1) ON/OFF switching of OSD menu display
OSD menu display is set to ON as factory default with FC series camera.
The example of the way to turn off OSD menu is shown below.
Select the item " TakexCameraControl > OSDMenu > FCMenu "
→ Select "off " and press the return key.
(Note) It is essentially possible to change parameters and reflect it to the
camera while displaying images, in the case that the selected item is
indicated in deep color during streaming images (displaying images),
however streaming may be interrupted sometimes and display status
may get unstable.
In that case, change settings after clicking "STOP" (red colored
button) and stopping display.
(Example2) MGC gain setting
The example of the way to change MGC gain setting is shown below.
Select the item " AnalogControl > GainRaw " and enter the numerical
number. The range of numerical number is 0 to 255 for FC-GE series
camera. It is possible to either increase or decrease the number in
increments of one by directly entering the numerical number or by
clicking the up-down arrows to the right of the entry field.
→ Set value is reflected to the camera by pressing the return key after
having changed the numerical number or by selecting the other item.
(Example3) Exposure time setting – Continuous shutter – Direct designation
of shutter speed
The example of the way to directly designate the shutter exposure time
(e.g. 1000) in continuous shutter mode is shown below.
Set the following set of parameters.

Set to "Timed" on the item "AcquisitionAndTriggerCntrols > ExposureMode

Set to "ExposuTime" on the item "AcquisitionAndTriggerCntrols > PresetShutter

Enter "1000" on the item "AcquisitionAndTriggerCntrols > ExposureTimeRaw".
And press the return key.