6-10. GPI SETUP
Please refer to 7. Remote Terminal Assignment for detailed information
█ Remote ID Number
Using SERIAL PORT (RJ-11) and Wall System Control Software, when remote
control, it sets own number for each monitor. ID Number is available to be
assigned from 0~99. Or IR Remote control, it sets monitor body number.
(Option)
█ Serial Remote
Selects use BON or TSL v4.0 mode.
Selects whether use external SERIAL PORT (RJ-11) control or not.
If Serial Remote is ON, then, it becomes Standby, with the exception of MENU
button, the other buttons does not operate.
To Terminate Serial Remote Status (Update, Remote On), press
!
Menu Button more than 3 seconds.
█ GPI Control
Used to select external control terminal
(GPI PORT / RJ-45) ON/OFF. It is not
possible to control through Remote
terminal from outside of external area
when it is OFF.
█ GPI Port 1, 2, 3, 4, 5, 6, 7
Used to select each terminal of external
Remote Control Terminal. However, GPI
Port 7 is fixed as Key Standard.
-- 37 --