5.8
Test modes, English
- 20: Serial communication overrun error
Expected command byte, but received a data byte.
- 22: Serial communication noise error
Check sum did not match.
- 23: Serial communication software error
Queue full.
- 37: Selection error
Unknown command
OS: Error in the operation system.
- 08: IL TLG from APOS to FEP
- 09: IL RX TX BUF limit
- 13: FEP does not exist
IO: Last error in the I/O driver.
- 01: IIC1 2 error
- 05: Cannot confi gure FEP
- 06: FEP communication error
- 07: IL TGL from FEP to APOS
- 08: IL TGL from APOS to FEP
- 09: Interlink RX TX BUF limit
- 14: FEP does not exist
- 33: MLSL timeout error
- 34: MLSL TX BUF full TLG does not send
- 35: ML key lost key repaired
- 36: External communication not allowed in preproject
- 37: LSL format error
- 38: LS IR format error
- 39: LSL TX imposs
- 40: LSL link tied up
- 41: LSL link tied down
- 42: Generic ICB error
- 43: ICB L7 timeout
- 44: ICB L7 illegal timeout
- 45: ICB L7 out of repositories
- 46: ICB L7 illegal L7 ack
- 47: ICB L7 Acknowledge unexpected
- 48: ICB L7 read response unexpected
- 49: ICB L7 illegal resource type
- 50: ICB L7 resource still running
- 51: ICB L7 resource already free
- 52: ICB L7 illegal IOP service
- 53: ICB L7 illegal IOP object
- 54: ICB L7 telegram fl ushed
- 55: ICB L7 resource disabled
- 56: ICB L7 HW clock illegal command
- 57: ICB L7 HW clock illegal event
- 58: ICB L2 retrans limit reached
- 59: IIC component disabled
- 60: CDS bus disabled
- 61: Power down of IOP impossible

Advertisement