ML: Last error regarding to ML.
- 08: Link tied down
It is impossible to transmit on Master Link because it is pulled low. The error may
occur if there is an error in the Master Link driver circuit, or because a short circuit
has occurred on the Master Link.
- 16: Link tied up
It is impossible to transmit on Master Link because it is pulled low.
The error may occur either because the pull-up resistance in the system has
become too low or as a result of an error in the data receiver circuit.
- 32: Confi guration impossible
Disconnect all products from the Master Link system and reconnect them one by
one until the error shows up.
IIC: Component which gave the last error regarding IIC-bus.
- 102: Tuner FEP
- 104: Motor FEP
- 136: Sound Processor
- 208: Clock
SER: The last error from the RS232 driver.
- 01: CDA queue not attached
SW communication error
- 02: CDA error timeout
SW communication error
- 03: CDA error unknown buf addr
Communication error. Check the bus and the components connected to it.
- 04: CDA error data expected
Communication error. Check the bus and the components connected to it.
- 05: CDA error unknown CMD
Communication error. Check the bus and the components connected to it.
- 06: CDA error checksum
Communication error. Check the bus and the components connected to it.
- 07: CDA error RX timeout
SW communication error
- 08: CDA error out of buffers
- 09: CDA error uart overrun
- 10: CDA error uart framing
- 11: CDA error uart parity
CD: CD error.
- 02: Focus error
The CD could not focus within the time limit.
- 03: Radial error
Set when the CD did not get on track after several retries.
- 04: Turntable motor error
Set when the disc did not spin up or down within the time limit.
- 05: PLL lock error
Set when PLL is out of lock during tracking mode.
- 06: Jump error
Set when a seek could not be performed or an error occured during a binary search.
- 07: Subcode error
Set when a subcode could not be read within the time limit.
- 08: TOC read error
Set when the TOC could not be read, no access possible to lead-in.