MODIFIED TRAPEZOIDAL AREA X VELOCITY, P3 = 15

'U' parameters listed *
U0 = channel top width
U1 = channel base width
U2 = transition height
*obtain from manufacturer's specifications.
**
calculated by OCM-3. May be viewed by accessing 'U' parameter.
Reference
ABSOLUTE CALCULATION, P4 = 0
For flows that can be calculated by the equation:
q = 1/1000 x (b + mh) x v
q = 1/1000 x ((b + md)d + (B(h - d))) x v for h ≥ d
m = (B - b)/d
where :
q = flow rate, l/s
B = channel top width, cm
b = channel base width, cm
RATIOMETRIC CALCULATION, P4 = 1
For flows that can be calculated by the equation:
q = q
x A/A
x v/v
cal
cal
for h ≤ d: A = (b + mh) x h
A
= (b + mh
cal
for h ≥ d: A = (b + md) x d + B(h - d)
A
= (b + md) x d + B(h
cal
m = (B - b)/d
where :
q = flow rate
q
= flow rate at h
cal
B = channel top width, cm
b = channel base width, cm
¤
Refer to Operation \ Flow Calculation.
7ML19985AB01
B
b
ht
¤
for h ≤ d
¤
cal
) x h
cal
cal
- d)
cal
cal
OCM III
'U' parameters calculated **
U3 = area (h)
d = height of transition, cm
h = head, cm
v = flow velocity, cm/sec
d = depth of channel
h = head
v = flow velocity, cm/sec