Trapezoidal Area X Velocity, P3 =14 - Siemens OCM III Instruction Manual

Open channel flow meter
Table of Contents

Advertisement

TRAPEZOIDAL AREA X VELOCITY, P3 = 14
'U' parameters required *
U0 = channel top width
U1 = channel base width
U2 = channel depth
*
obtain from manufacturer's specifications.
**
calculated by OCM-3. May be viewed by accessing 'U' parameter.
Reference
ABSOLUTE CALCULATION, P4 = 0
For flows that can be calculated by the equation:
q = 1/1000 x (b + mh) x v
m = (B - b)/d
where :
q = flow rate, l/sec
B = channel top width, cm
b = channel bottom width, cm
d = depth of channel, cm
h = head, cm
v = flow velocity, cm/sec
RATIOMETRIC CALCULATION, P4 = 1
For flows that can be calculated by the equation:
q = q
x A/A
x v/v
cal
cal
A = (b + mh) x h
A
= (b + mh
) x h
cal
cal
m = (B - b)/d
where :
q = flow rate, l/sec
B = channel top width, cm
b = channel bottom width, cm
d = depth of channel, cm
h = head, cm
v = flow velocity, cm/sec
¤
Refer to Operation \ Flow Calculation.
7ML19985AB01
B
b
ht
¤
¤
cal
cal
OCM III
'U' parameters calculated **
U3 = area (h)
84