Lenovo x3250 m6 Installation And Service Manual page 410

Hide thumbs Also See for x3250 m6:
Table of Contents

Advertisement

No
Alert Category
System - Other
SNMP Trap ID
22
CIM Information
Prefix: PLAT ID: 0142
User Response
1. Reseat the DIMM, and then restart the server.
2. Replace DIMM n. (n = DIMM number)
806f090c-2004ffff : [PhysicalMemoryElementName] on Subsystem [MemoryElementName]
Throttled. (DIMM 4)
This message is for the use case when an implementation has detected Memory has been Throttled.
May also be shown as 806f090c2004ffff or 0x806f090c2004ffff
Severity
Warning
Serviceable
Yes
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
22
CIM Information
Prefix: PLAT ID: 0142
User Response
1. Reseat the DIMM, and then restart the server.
2. Replace DIMM n. (n = DIMM number)
• 806f0a07-0301ffff : [ProcessorElementName] is operating in a Degraded State. (CPU 1)
This message is for the use case when an implementation has detected a Processor is running in the
Degraded state.
May also be shown as 806f0a070301ffff or 0x806f0a070301ffff
Severity
396
Lenovo System x3250 M6 Installation and Service Guide

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents