Lenovo x3250 m6 Installation And Service Manual page 340

Hide thumbs Also See for x3250 m6:
Table of Contents

Advertisement

Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0184
User Response
This is a UEFI detected event. The UEFI(POST) error code for this event can be found in the logged
IMM message text. Please refer to the UEFI(POST) error code in the "UEFI(POST) error code" section
of the Information Center for the appropriate user response. Firmware Error : Sys Boot Status :
• 806f0013-1701ffff : A diagnostic interrupt has occurred on system [ComputerSystemElementName].
(NMI State)
This message is for the use case when an implementation has detected a Front Panel NMI / Diagnostic
Interrupt.
May also be shown as 806f00131701ffff or 0x806f00131701ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0222
User Response
If the NMI button has not been pressed, complete the following steps:
1. Make sure that the NMI button is not pressed.
2. Replace the operator information panel cable.
3. Replace the operator information panel.
806f001e-2201ffff : No bootable media available for system [ComputerSystemElementName].
(No Boot Device)
This message is for the use case when an implementation has detected a System with No Bootable Media.
May also be shown as 806f001e2201ffff or 0x806f001e2201ffff
326
Lenovo System x3250 M6 Installation and Service Guide

Hide quick links:

Advertisement

Table of Contents
loading