Lenovo x3250 m6 Installation And Service Manual page 408

Hide thumbs Also See for x3250 m6:
Table of Contents

Advertisement

3. Check for a server firmware update. Important: Some cluster solutions require specific code
levels or coordinated code updates. If the device is part of a cluster solution, verify that the latest
level of code is supported for the cluster solution before you update the code.
4. Make sure that the two microprocessors are matching.
5. (Trained technician only) Replace the system board.
806f0823-2101ffff : Watchdog Timer interrupt occurred for [WatchdogElementName]. (IPMI
Watchdog)
This message is for the use case when an implementation has detected a Watchdog Timer interrupt
occurred.
May also be shown as 806f08232101ffff or 0x806f08232101ffff
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0376
User Response
No action; information only.
806f090c-2001ffff : [PhysicalMemoryElementName] on Subsystem [MemoryElementName]
Throttled. (DIMM 1)
This message is for the use case when an implementation has detected Memory has been Throttled.
May also be shown as 806f090c2001ffff or 0x806f090c2001ffff
Severity
Warning
Serviceable
Yes
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
394
Lenovo System x3250 M6 Installation and Service Guide

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents