Section 4B: SensorWireConnections - Nabco GT 1175 Installation Manual

With u30 microprocessor controller
Hide thumbs Also See for GT 1175:
Table of Contents

Advertisement

www.NabcoEntrances.com
Rev. 8-25-16
10
BA
Terminal #
Symbol
11
SLS
12
OUT A
13
OUT B
14
OUT C
15
OUT
16
7
Section 4b: Sensor Wire Connections
* Color1/Color2 denotes a base wiring Color 1 with a stripe Color 2. For example: Black/Red
indicates a Black wire with a Red Stripe.
** Denotes wiring that has been crimped together at NABCO factory.
Table 4-1 Acusensor
Red
U30 Harness
Black
Signal, Interior
*Black/Red
Signal Exterior
Brown
IdentifyOperatingWires
Blue
X Input terminal
Color
• Breakout Detector signal.
• Connected to Red (7) during normal operation.
• Disconnected from Red (7) during 'stop door' operation. Will
happen if:
• Switch is turned OFF
• Slide door is panicked open
Green/
X Input terminal
White*
• Sidelite Presence Sensor.
• At fully closed position, input will prevent Slide door from opening.
Gray
X Auxiliary Output terminal
• Connected to Normally Open contact on an internal relay.
• Referred to as ' A uxiliary Relay Output" throughout manual.
• Used as a Switch to:
• Sequence an Electric Strike.
• Control other Slide doors in an air lock situation.
• Signal a remote computer on the Slide door operation.
Gray
X Auxiliary Output terminal
• Connected to Normally Closed contact on an internal relay.
Violet
X Auxiliary Output terminal
• Common for output wire "OUT A" or 'OUT B"
Brown/
X Auxiliary Output 2 terminal
Yellow*
• Connected to an Internal Transistor with Open Collector in the U30
Microprocessor Controller.
• Installer must provide wire for this terminal (not normally utilized).
Red
X Common terminal
• Provides common ground for the 12 VDC power and signal source.
Common
+12 VDC
Description
Red
Extension Harness
Yellow
Gray
ElectricalInstallationManualU-30"D"Control
**White and Red
Acusensor Harness
Green
Black
Part #C-00121
4-11