www.NabcoEntrances.com
Rev. 8-25-16
Rocker Switch
Key Switch
One Way
Mode
Mode
Full Open
Reduced Open
Reduced
IdentifyOperatingWires
Wire
Wire
Exit
ON
OFF
M0
M1
Full
-
-
-
-
ElectricalInstallationManualU-30"D"Control
Wire
X Sensor on Terminal (3) can open the door.
H
• Sensor is normally Interior and used to activate door
-
for one-way traffic.
X Sensor on Terminal (8) can not open the door from the
closed position.
• Sensor is normally Exterior and used to provide
threshold safety only.
• Electric Lock remains locked unless an activation
occurs from the interior sensor or by a device (such
as a card reader, key switch, wall plate, etc.) that is
connected in one of two ways:
1.►Between Common and M1 (6)
a.►This only works when door is in "One Way" or
"Exit" mode.
2.►Between Common and SLS (11)
a.►This only works if the SLS is programmed for
activation devices.
Note: Consult the U30 Programming Manual for details;
OFF
X Upon activation or in Hold Open mode, Slide door will
(P/N 15-9000-30).
open to the full position.
ON
X Upon activation, Slide door will open to the Reduced
Open position.
Part #C-00121