Chapter 7: Electric Lock Wiring; Section 7A: AdjustTheStrike - Nabco GT 1175 Installation Manual

With u30 microprocessor controller
Hide thumbs Also See for GT 1175:
Table of Contents

Advertisement

www.NabcoEntrances.com
Rev. 8-25-16
CHAPTER 7: ELECTRIC LOCK WIRING
Note:
 Electric Locks can not prevent Breakout. If preventing Breakout is deemed necessary, panic
hardware must be fitted to the Door Panels.
The Electric Lock is optional and can come in (1 of 2) configurations:
► Fail Safe
► Fail Secure
Electric Locks are used to prevent Door Panels from opening until they are activated by the U30
Microprocessor Control when it receives a signal from a:
► Remote Switch
► Transmitter
► Activation Device on the face of the Door
Electric Locks are pre-installed at the NABCO Factory. Only the Strike mounted on the Header may
need to be adjusted.
Section 7a: Adjust the Strike.
1.►Close Door Panel(s).
2.►Go inside the Header. Loosen the Strike Mounting Bolts that is holding the Strike Bracket
3.►Slide the Strike to align with the Latch Bolt in the fully closed position.
4.►Tighten the Strike Mounting Bolts.
LATCHBOLT POSITION:
• BI PART UNITS
• LH SINGLE F.O.
• RH SINGLE F.S.
LATCHBOLT POSITION:
• RH SINGLE F.O.
• LH SINGLE F.S.
ElectricLockWiring
Allows the Door Panel to be manually opened if power is turned Off.
Will not allow the Door Panal to be manually opened if power is turned Off.
secure to the Header.
a.
Do not overtighten.
Electric Strike
Electric Lock Assembly
Slight Gap
(Between Strike Wall
and Dead Bolt)
Belt Clip
Dead Bolt Assembly
ElectricalInstallationManualU-30"D"Control
Dead Bolt Engaged with Electric Strike
(Door in Full Closed Posi on)
Figure 7-1 Adjust the Strike
Part #C-00121
Terminal Strip
(Strike Side of Door)
DN 1026
7-23