5.3 PRINTER ENGINE SERVICE MODE

5.3.1 SERVICE MODE TABLE ('2. ENGINE MAINTE')

Service
Description
Mode
Regist sag
Paper feed
timing
Fusing
Fusing power
Control
control
Fusing
Fusing
Temp
temperature
adjustment
Fusing
Fusing
T Dis
temperature
display
OHP
Bypass paper
Clutch Rt
feed roller
rotation for
transparencies
Fusing
Initial fusing
Start
setting
Curl
Low temperature
Control
fusing
Charge
Charge roller
Rol Bias
voltage
adjustment
Mainscan
Main scan
mag
magnification
adjustment
Subscan
Sub scan
mag
magnification
adjustment
Developer
Development
Bias
Bias Adjustment
Toner End
Number of prints
Count
after toner near-
end is detected
G056/G058
Function
Adjusts the paper feed clutch timing at
registration. The paper feed clutch
timing determines the amount of paper
buckle at registration. (A larger setting
leads to more buckling.)
Selects whether the fusing power
control is on/off or phase control.
Use "Phase" control if the room lights
flicker when the fusing lamp starts.
Adjusts the fusing temperature for
printing.
Normally, do not change the setting.
Displays the fusing temperature.
Selects the number of rotations for the
bypass tray feed roller when the paper
type is set to "Transparencies."
This is to avoid jams when
transparencies are being used.
Roller turn: Warms up the fusing unit for
20 s at power on or when the machine
warms up from the energy saver mode.
Normal: There is no 20 s warm-up
period
Select 'roller turn' to avoid poor fusing in
a low temperature environment.
Lowers the fusing temperature (to
150°C) to prevent thin paper from
curling. Use this mode only when a
paper jam occurs during duplex rear
side printing.
Adjusts the charge roller voltage.
Normally, do not change the setting.
Adjusts the main scan magnification.
Adjusts the sub scan magnification.
Adjusts the development bias for
printing.
Normally, do not change the setting.
Adjusts the number of prints the
machine can print after it detects toner
near-end.
5-4
Setting
-8.0 to +8.0
2 mm/step
0 mm
Normal
(US)
Phase
(Europe/Asia)
100 to 200
10°C/step
170°C
1 (1 rotation)
2 (2 rotations)
Normal
Roller turn
Normal
Curl control
1000 to 2000
10 V/step
1650V
-0.5 to +0.5
0.1 %/step
0 %
-0.5 to +0.5
0.1 %/step
0 %
-800 to -200
10 V/step
-700V
50 to 200
50 sheets/step
200 sheets
SM