Fronius Selectiva 2040 2kW Operating Instructions Manual page 32

Battery charging system
Hide thumbs Also See for Selectiva 2040 2kW:
Table of Contents

Advertisement

-
-
-
Delay:
charge start delay:
Delay time (minutes) of actual start of charging relative to the moment when charge start
was initiated
Charge end delay:
Delay time (minutes) before charge end is signalled (e.g. green indicator) relative to the
moment when charging actually stopped
At mains failure restart charging:
If this option is chosen, the charging process is restarted automatically as soon as the
mains supply becomes available again after a disruption to the electrical mains supply.
Calendar:
The calendar function allows charging to be started automatically according to the follow-
ing criteria:
-
-
-
Additional settings can be found under the "Calendar" function:
32
OFF:
There is no equalising charge.
Delay:
If the battery remains connected to the charger for the duration of the "equalize charge
delay", then a special type of charging takes place. This prevents acid stratification.
Weekday:
Specify the weekday on which the equalising charge is to take place.
Time window in which charging may not be started if a battery is connected
Time window in which charging is to be started using a defined characteristic 1 if a bat-
tery is connected
Time window in which charging is to be started using a defined characteristic 2 if a bat-
tery is connected
To activate the calendar function,
1
select the "ON" setting and confirm
The first menu item "Charging settings" al-
lows three characteristics to be defined:
-
Type of battery for every characteristic:
e.g. Pb-Wet
-
Curve settings when selecting the rele-
vant characteristic
Day Setting 1-5:
The day settings allow up to five different
charging start time profiles to be defined
with the following settings: