NOTE! Ongoing charging operations are unaffected by the set time windows. If in
the example above a battery is connected at 05:45, the charge end time is gov-
erned according to need and is not interrupted by the end time specified for the
set time window (06:00 in the example).
If the battery is connected during the "stop" time window, charging is started au-
tomatically during the next time window.
If charging is started manually during the "stop" time window, charging will always
take place using characteristic 1.
-
Symbol for characteristic 1:
Time window in which charging is to be
started using characteristic 1 (e.g.
0:00-6:00)
-
Stop:
Time window in which charging must
not take place (e.g. 06:00-20:00)
-
Symbol for characteristic 2:
Time window in which charging is to be
started using characteristic 2 (e.g.
20:00-24:00)
Additional settings:
-
Change the allocated characteristic:
characteristics symbol
-
Remove the selected characteristic:
"remove"
Week Setting:
-
Three different week settings can be
defined.
A previously created day setting can be as-
signed to any day of the week.
Year Setting:
-
Multiple periods throughout the year
may be defined, each containing a
single week setting (e.g. 1/1 - 7/1).