9.0 RESET CONFIGURATION TO FACTORY DEFAULTS

The configuration can be reset to factory defaults from the software reset
mode. This allows a user to recover from a forgotten password. To reset
to the configuration, follow these steps:
1. Power down the unit.
2. Set all DIP switches to the OFF position.
3. Connect a PC to the Console port.
4. Open a VT100 terminal emulator (such as HyperTerminal). Config-
ure the emulator for 19,200 kbps/1 stop bit/no parity/X-ON X-OFF
flow control.
5. Power up the unit. The terminal should display the following mes-
sage: "Reset Mode".
6. Type the '*' key. You will see a ': ' prompt.
7. Type the command 'reset'.
8. When the command completes, the unit has been reset to
factory configuration.
9. Set the DIP switches to the desired configuration. Power cycle the
unit to begin using the new software.