You can select the LCD connector CN3 (pin 5 and pin 6) driving
voltage by setting J3 and J11. The configuration as follows:
J3
J11
*default
You can select the LCD control signal by setting (J5) & (J6). The
following charts show the available option.
SHF CLK
J5
J6
You can use J7 to clear the CMOS data if necessary. To reset the
CMOS data, set J7 to 2-3 closed for just a few seconds, and then
move the jumper back to 1-2 closed.
Protect (default)
1
5V*
1
2 3
1
2 3
2 3
3.3V
1
2 3
1
2 3
ASHF CLK
Clear CMOS
1
2 3