NOTICE: It is necessary to remove the Shrouds for this procedure. Refer to the "Replace the Shrouds" procedure.
To reduce the risk of electrical shock or unsupervised usage of the equipment, always unplug the power cord from the wall outlet and wait 5
minutes before cleaning, maintaining or repairing this machine. Place the power cord in a secure location.
Note: Your machine may not match the image. For reference only.
Carefully remove the Shrouds. Refer to the "Replace the Shrouds"
1.
procedure in this manual.
Observe the cable routing from the RPM Sensor (A) to the wiring
2.
harness (C) on your machine. Carefully disconnect the RPM Sensor cable
(B) from the wiring harness.
Remove the hardware that attaches the RPM Sensor (A) to the Main
3.
Frame. Carefully remove the old RPM Sensor and cable and discard it.
NOTICE: Do not crimp any cables.
Installation is the reverse procedure.
4.
NOTICE: Do not crimp any cables. Be sure the routing for the
new RPM Sensor cable (B) and other wiring is correct to
prevent interference from moving parts.
Note: Before fully attaching the Shrouds, verify that the RPM Sensor
(A) and Speed Sensor Magnet (D) on the Drive Pulley do not
touch.
5.
Final Inspection
Inspect your machine to ensure that all hardware is tight and components
are properly assembled.
Do not use until the machine has been fully assembled and
inspected for correct performance in accordance with the
Owner's Manual.
Upright bike
A
C
Recumbent bike
C
59
D
B
A
D
B