Troubleshooting

Symptom
No power, or none of the
system LEDs are lit.
Power-Up Self-Test fails.
Only Alarm LED is on
after power-up.
Cannot access the NAM
or the user interface.
Device Fail appears on
the System Health and
Status screen.
Not receiving data at
DTE or DSX-1 interface.
Possible Cause
For DC power source, DC
power is not present.
For AC power source, the
wall receptacle has no
power, or the housing's
power cord is not securely
plugged into the wall
receptacle or the back of
t e ous g
the housing.
LED is burned out.
The NAM has detected an
internal hardware failure.
Login or password is
incorrect, COM port is
misconfigured, or the NAM
otherwise configured so it
prevents access.
The NAM detects an
internal hardware failure.
Not cross-connected to the
correct timeslot(s).
11
Solutions
Check the DC power
source.
1. Check the wall
receptacle power by
plugging in some
equipment that is known
to be working.
2. Check that the power
cord is securely attached
cord is securely attached
at both ends.
3. Check the circuit
breaker.
Run the Lamp Test. If the
LED in question does not
flash with the other LEDs,
then contact your service
representative.
1. Reset the NAM and try
again (see the Technical
Reference).
2. Contact your service
representative.
1. Reset the NAM (see the
Technical Reference).
2. Contact your service
representative.
Record the 8-digit code
from the System Health
and Status screen, then
contact your service
representative.
Verify cross connections
using the Cross Connect
configuration option.