Everlast PowerMTS 251Si Operator's Manual page 16

Table of Contents

Advertisement

Section 2
TIG (GTAW) OPERATION GUIDE FOR STEEL (ALUMINUM)*
*As a general rule, set amperage using 1 amp for every .001" of metal thickness for aluminum. Less is required for DC.
METAL THICKNESS
1-3 mm/.040"-1/8"
3-6 mm/ 1/8"-1/4"
6-10 mm 1/4"-3/8"
METAL THICKNESS
< 1 mm/.040"
2 mm/.080"
3 mm/ 1/8"
4-5 mm/ 3/16"
6-10 mm/ 1/4"-3/8"
TYPE
Pure
100% Tungsten
Thoriated
2% Thorium
(slightly radioactive)
Ceriated
2% Ceria
Lanthanated
1.5% Lanthanum Gold
Lanthanated
2% Lanthanum
Zirconiated
1% Zirconia
Setup Guide and Component Identification
WELDING AMPS
(A)
40-80 (60-125)
80-200 (125-200) 2-3 mm/ 3/32"-1/8" 15-25 CFH/ 7-14 lpm
150-200 (200-250) 3-6 mm/ 1/8"-1/4"
STICK (SMAW) OPERATION GUIDE
TUNGSTEN SELECTION GUIDE FOR AN INVERTER
PERCENT
COLOR
Green
Red
Orange
Blue
Brown
TUNGSTEN DIA.
1-2 mm/.040"-3/32" 8-15 CFH /4-7 lpm
ELECTRODE SIZE
1.5 mm/ 1/16"
2 mm/3/32"
3.2 mm/1/8"
3.2-4 mm/ 1/8"
4–5 mm/ 1/8"-5/32"
PROCESS
AC
NOT RECOMMENDED!
Do not use in an inverter.
AC/DC
YES. Great for all purpose welding. Most eco-
nomical.
AC/DC
YES. Good for low amp use.
AC/DC
YES. Best alternative to 2% Thoriated. Tough
performer.
AC/DC
YES. Slight advantage over 1.5% Lanthanated.
AC
NOT RECOMMENDED!
Do not use in an inverter.
16
Ar FLOW RATE
20+ CFH/10-15 lpm.
WELDING AMPS
20-40
40-90
90-110
90-130
130-200
RECOMMENDATION

Advertisement

Table of Contents
loading

Table of Contents