Technical Parameters - Everlast PowerMTS 251Si Operator's Manual

Table of Contents

Advertisement

Section 1
MODEL: PowerMTS 251Si
1~
f
1
f
2
S
S
S
1~ 50/60 Hz
PROTECTION
CLASS
IP21S
*60 IPM is based on minimum useable feed rate.
NOTE: Environment, Maintenance and Safety: Keep this welder at least 12 inches away from all objects for proper cooling.
Do not exceed 40° C in environment or duty cycle will be reduced. Regularly inspect and clean the welder and circuitry on a
monthly basis with dry compressed air. Remove the covers only after the unit has been turned off and unplugged for 30
minutes to discharge the capacitors and to prevent the possibility of electrocution. Do not grind or direct sparks near the
welder to prevent damage to the panel face and internal components. Damage of this nature is not covered by the warranty.
L: 660mm/26"
W: 286mm/ 11.25"
EVERLAST
POWERMTS 251Si
Serial No.
240V; DC: 30-250A; 15.5-26.5V
X
40%
U
V
I2
250A
0
60V
U2
26.5V
240V; DC: 10-250A; 10.4-20V
X
40%
U
V
I2
250A
0
60V
U2
20V
240V; DC: 10-200A; 20.4– 28V
X
40%
U
V
I2
200A
0
60V
U2
28V
U
1
120-240V
COOLING METHOD:
DUAL, FULL-TIME FAN
H: 457 mm/18"
Introduction and Specifications
EN/ IEC60974.1
120V; DC: 30-150A; 15.5-21.5V
60%
100%
40%
200A
160A
150A
24V
22V
21.5V
120V; DC: 10-150A; 10.4-16V
60%
100%
40%
200A
160A
150A
18V
16.4V
16V
120V; DC 10-120A; 20.4V-24.8V
60%
100%
40%
160A
130A
120A
26V
25.2V
24.8V
120V I
36A I
1MAX:
1EFF
240V I
37A I
MAX:
1EFF
1
INSULATION: F
Bare Weight: 32kg/70 lbs.
10
60%
100%
120A
90A
20V
18.5V
60%
100%
120A
90A
14.8V
13.6V
60%
100%
95A
70A
23.8V
22.8V
22.8A
23.2A
WIRE SPEED:
240V: 60*-600 IPM
120V: 60*-400 IPM

Advertisement

Table of Contents
loading

Table of Contents