False Nxge Warning Messages (Cr 6938085); Fault.memory.memlink-Uc Interconnect Fault Did Not Cause Panic As Stated By Knowledge Article (Cr 6940599) - Sun Oracle Netra SPARC T3-1B Product Notes

Hide thumbs Also See for Netra SPARC T3-1B:
Table of Contents

Advertisement

USB drives connected to the front dongle cable or the internal USB port might fail
after running the Oracle VTS disktest for over 5 hours.
Note – USB ports are only supported for troubleshooting purposes. The ports are
not supported for general operation.
Workaround: Stop any application that is using the USB port. Then reset the USB
port with the cfgadm -x usb_reset [...] command.

False nxge Warning Messages (CR 6938085)

This issue is fixed in the Oracle Solaris 10 8/11 OS.
During the normal operation of your server, you might see the following warning
messages in the system console or in the Oracle Solaris /var/adm/messages file:
date/time machinename nxge: [ID 752849 kern.warning] WARNING: nxge0 :
nxge_hio_init: hypervisor services version 2.0
Workaround: These messages are harmless, and you can ignore them.
fault.memory.memlink-uc Interconnect Fault
Did Not Cause Panic as Stated by Knowledge
Article (CR 6940599)
When a fault.memory.memlink-uc interconnect fault is detected, the system
should shut down to protect memory integrity. On intermittent occasions, this fault
has been reported during boot operations without the system shutting down.
Although it is possible that this irregular behavior indicates that the system was able
to recover from the memory link error and restore a healthy boot-up state, the safest
action is to perform a power-down and power-up sequence.
Recovery: Power cycle the server module.