Care & Maintenance Of The Gemini Hub - Gemini 620pd Profiling Product Manual

Profiling system
Table of Contents

Advertisement

9. Care & Maintenance of the Gemini Hub
There are no user serviceable parts within the Gemini Hub and no maintenance should
be required.
The unit should be operated in a rack mount which is dry, free from excessive dust
and has a good supply of cool air.
If it becomes necessary to change the main fuse of the unit the following procedure
should be used:
1. Turn off power and remove the power lead from the unit.
2. Locate the fuse holder in between the switch and the power-in socket.
3. Pull out the fuse holder and replace fuses with two of the correct specification (see
Section 7.3, "Electrical and Communication").
4. Re-insert the fuse holder and ensure it is properly seated.
5. Re-connect the unit and test operation.
0695-SOM-00001, Issue: 03
Caution
Do not expose the Gemini Hub to moisture.
Warning
Do not remove the cover of the hub unit - doing so may expose the user
to risk of electrical shock
31
Gemini Profiling System
© Tritech International Ltd.

Advertisement

Table of Contents
loading

Table of Contents