Network Configuration - Gemini 620pd Profiling Product Manual

Profiling system
Table of Contents

Advertisement

11. Network Configuration

To properly configure the Gemini devices on a network it will be necessary to set the
IP addresses of the devices in the correct order otherwise a situation may arise where
a particular device is unreachable. If a device does become unreachable then it may
be necessary to separate it from the rest of the system to undergo fault finding.
To set the IP address of the Gemini System devices:
1. Set the IP address of the computer 192.168.2.100 with a subnet mask of
255.255.255.0
2. Change the IP address of the Gemini Profiler from the default value
(192.168.2.201) to the desired value. The status information will remain in
the Gemini Software but it will no longer be possible to communicate with the
Gemini Profiler at this point.
3. Set the IP address of the Gemini Hub from the default value (192.168.2.101)
to the desired value and close the Gemini Software
4. Set the computer to the desired IP address (on the same subnet as previously set
for the Gemini Profiler and Hub)
5. Restart the Gemini Software and both the Hub and Profiler should now be able
to communicate.
0695-SOM-00001, Issue: 03
Setup on a complex network
The steps outlined here assume that the network consists only of the
computer running the Gemini software, the Gemini Hub and a single
Gemini Profiler. If the system is more complex it may be necessary to turn
off or disconnect ancillary devices in order to simplify the connection and
configuration process. If two Gemini Profilers are in use then it will be
necessary to connect them one at a time otherwise communication with
them will not be possible because they will both be using the default IP
address.
Note
For instructions on setting the computer IP address please refer to
Appendix B, Setting the computer IP address in Windows 7 or
Appendix A, Setting the computer IP address in Windows XP.
Note
For instructions on setting the Gemini Hub or Gemini Profiler IP address
please refer to Appendix C, Setting the Gemini Device IP Address in
Gemini Software.
35
Gemini Profiling System
© Tritech International Ltd.

Advertisement

Table of Contents
loading

Table of Contents