Gemini Hub - Gemini 720i Product Manual

Imaging sonar
Hide thumbs Also See for 720i:
Table of Contents

Advertisement

Gemini Software Operation

5.3.2. Gemini Hub

Hubs Tab
The Hubs tab shows the status information from any connected Gemini Hubs.
Hub Setup Tab
The Hub Setup tab allows configuration of the serial ports on the rear of the Gemini Hub to
allow RS232 data to pass through to the Gemini software from external sensors.
Port
Mode
Sync
Baud
Decode
Max
Age
Hz
String
Document: 0685-SOM-00001, Issue: 11
The port letter, corresponding to the label on the back of the Gemini
Hub.
Can change between an ASCII decode, binary decode or can echo
the data on one of the other ports (ASCII is the default input, only the
Simrad EM3000 uses a binary input). Echo is used as an alternative to
a serial splitter cable in systems where the sensor data is also used by
another application or device.
The sync character used to frame the ASCII string.
The baud rate of the sensor connected to the port.
The decode definition to apply for the expected receive data on the port.
Set the time in seconds to generate an alarm if no data is received.
The age of the data, shows when the last good data was received (see
note below).
The incoming data rate
The incoming data string, check this against the chosen Decode if the
data indicator is red.