Problems And Solutions - SPHINX Myth11 Service Manual

Table of Contents

Advertisement

SPHINX Myth 11

7. PROBLEMS AND SOLUTIONS

At the moment of writing the Myth 11 has one
known specific problem.
If in the future you encounter any problem(s) you
may enter the info in this table. This table can then
be used for future reference.
Problem
Protection activates
Hum at the output.
Modified from November 1998.
Cause
Temperature of amplifier is too
high
Cinch input connector not
modified.
Service Manual
Please also send (by fax or e-mail) the specific
information to the Sphinx International Service
Department (see page 3): this info can then be
added to the general database to aid others.
Solution
Re-adjust bias
Separate the ground from L&R
cinch input and place a 10 Ohm
resistor between.
Refer to
page...
14/15
10
9