SLX.Er
Solutions Module slot X trip: Solutions Module in slot X has detected a fault
Feedback module category
Check value in Pr 15/16/17.50. The following table lists the possible error codes for the SM-Universal Encoder Plus, SM-Encoder
Output Plus, SM-Encoder Plus and SM-Resolver. See the Diagnostics section in the relevant Solutions Module User Guide for more
information.
Error code
0
1
2
3
4
5
6
7
202,207,212
8
9
10
11
12
13
14
15
16
74
Unidrive SP Free Standing User Guide
Issue Number: 1
Electrical
Getting
Basic
Installation
Started
parameters
Module
Trip Description
All
No trip
SM-Universal
Encoder Plus &
Encoder power supply overload
SM-Encoder
Output Plus
SM-Resolver
Excitation output short circuit
SM-Universal
Encoder Plus &
Wire break
SM-Resolver
SM-Universal
Phase offset incorrect while
Encoder Plus
running
SM-Universal
Feedback device communications
Encoder Plus
failure
SM-Universal
Checksum or CRC error
Encoder Plus
SM-Universal
Encoder has indicated an error
Encoder Plus
SM-Universal
Initialisation failed
Encoder Plus
SM-Universal
Auto configuration on power up
Encoder Plus
has been requested and failed
SM-Universal
Motor thermistor trip
Encoder Plus
SM-Universal
Motor thermistor short circuit
Encoder Plus
Failure of the sincos analog
SM-Universal
position alignment during encoder
Encoder Plus
initialisation
SM-Resolver
Poles not compatible with motor
SM-Universal
Encoder type could not be
Encoder Plus
identified during auto-configuration
Number of encoder turns read from
SM-Universal
the encoder during auto-
Encoder Plus
configuration is not a power of 2
Number of comms bits defining the
SM-Universal
encoder position within a turn read
Encoder Plus
from the encoder during auto-
configuration is too large.
The number of periods per
SM-Universal
revolution calculated from encoder
Encoder Plus
data during auto-configuration is
either <2 or >50,000.
The number of comms bits per
SM-Universal
period for a linear encoder
Encoder Plus
exceeds 255.
All
Solutions Module has overheated
www.controltechniques.com
Running the
SMARTCARD
Optimization
motor
operation
Diagnosis
No fault detected
Check encoder power supply wiring and encoder current
requirement Maximum current = 200mA @ 15V, or 300mA
@ 8V and 5V
Check the excitation output wiring.
Check cable continuity
Check wiring of feedback signals is correct
Check supply voltage or excitation output level
Replace feedback device
Check the encoder signal for noise
Check encoder shielding
Check the integrity of the encoder mechanical mounting
Repeat the offset measurement test
Ensure encoder power supply is correct
Ensure baud rate is correct
Check encoder wiring
Replace feedback device
Check the encoder signal for noise
Check the encoder cable shielding
Replace encoder
Check the correct encoder type is entered into Pr 15/16/17.15
Check encoder wiring
Check supply voltage level
Replace feedback device
Change the setting of Pr 15/16/17.18 and manually enter
the number of turns bits (Pr 15/16/17.09) and the equivalent
number of lines per revolution (Pr 15/16/17.10) and the
single turn comms bits (Pr 15/16/17.11)
Check motor temperature
Check thermistor continuity
Check motor thermistor wiring
Replace motor / motor thermistor
Check encoder cable shield.
Examine sine and cosine signals for noise.
Check that the correct number of resolver poles has been
set in Pr 15/16/17.15.
Check encoder type can be auto-configured.
Check encoder wiring.
Enter parameters manually.
Select a different type of encoder.
Select a different type of encoder.
Faulty encoder.
Linear motor pole pitch / encoder ppr set up is incorrect or
out of parameter range i.e. Pr 5.36 = 0 or Pr 21.31 = 0.
Faulty encoder.
Select a different type of encoder.
Faulty encoder.
Check ambient temperature
Check enclosure ventilation
Technical
Onboard
Advanced
Diagnostics
PLC
parameters
Data
Diagnostic