Emerson unidrive sp User Manual page 255

Universal variable speed ac drive for induction and servo motors model sizes 6 to 9
Hide thumbs Also See for unidrive sp:
Table of Contents

Advertisement

Safety
Mechanical
Product
Information
information
Installation
Trip
t216
User defined tripUser trip defined in 2
216
SM-Applications program must be interrogated to find the cause of this trip
th
Motor thermistor trip
Check motor temperature
24
Check thermistor continuity
Set Pr 7.15 = VOLt and reset the drive to disable this function
thS
Motor thermistor short circuit
Check motor thermistor wiring
25
Replace motor / motor thermistor
Set Pr 7.15 = VOLt and reset the drive to disable this function
tunE*
Autotune stopped before completion
The drive has tripped out during the autotune
18
The red stop key has been pressed during the autotune
The SAFE TORQUE OFF (SECURE DISABLE) signal (terminal 31) was active during the autotune procedure
tunE1*
The position feedback did not change or required speed could not be reached during the inertia test (see Pr 5.12)
Ensure the motor is free to turn i.e. brake was released
Ensure Pr 3.26 and Pr 3.38 are set correctly
11
Check feedback device wiring is correct
Check encoder coupling to motor
tunE2*
Position feedback direction incorrect or motor could not be stopped during the inertia test (see Pr 5.12)
Check motor cable wiring is correct
12
Check feedback device wiring is correct
Swap any two motor phases
tunE3*
Drive encoder commutation signals connected incorrectly or measured inertia out of range (see Pr 5.12)
Check motor cable wiring is correct
13
Check feedback device U,V and W commutation signal wiring is correct
tunE4*
Drive encoder U commutation signal fail during an autotune
Check feedback device U phase commutation wires continuity
14
Replace encoder
tunE5*
Drive encoder V commutation signal fail during an autotune
Check feedback device V phase commutation wires continuity
15
Replace encoder
tunE6*
Drive encoder W commutation signal fail during an autotune
Check feedback device W phase commutation wires continuity
16
Replace encoder
tunE7*
Motor number of poles set incorrectly
Check lines per revolution for feedback device
17
Check the number of poles in Pr 5.11 is set correctly
Unid.P
Power module unidentified trip
Check all interconnecting cables between power modules
110
Ensure cables are routed away from electrical noise sources
UP ACC
Onboard PLC program: cannot access Onboard PLC program file on drive
Disable drive - write access is not allowed when the drive is enabled
98
Another source is already accessing Onboard PLC program - retry once other action is complete
UP div0
Onboard PLC program attempted divide by zero
90
Check program
UP OFL
Onboard PLC program variables and function block calls using more than the allowed RAM space (stack overflow)
95
Check program
UP ovr
Onboard PLC program attempted out of range parameter write
94
Check program
UP PAr
Onboard PLC program attempted access to a non-existent parameter
91
Check program
UP ro
Onboard PLC program attempted write to a read-only parameter
92
Check program
Unidrive SP Free Standing User Guide
Issue Number: 1
Electrical
Getting
Basic
Running the
Installation
Started
parameters
nd
processor Solutions Module code
www.controltechniques.com
SMARTCARD
Optimization
motor
operation
Diagnosis
Technical
Onboard
Advanced
Diagnostics
PLC
parameters
Data
UL Listing
Information
255

Advertisement

Table of Contents
loading

Table of Contents