10. Proceed based on the result of the preceding step.
58
IBM System Storage: N6200 Series Hardware and Service Guide
sldiag device clearstatus
5. Verify that the log is cleared by entering the following command:
sldiag device status
The following default response is displayed:
SLDIAG: No log messages are present.
6. View the types of devices available for checking by entering the following
command:
sldiag device show
7. Run the test for the type of PCIe card you installed by entering the following
command at the Maintenance mode prompt:
sldiag device run -dev fcal|sas|ata|nic|toe
Note: See the IBM System Storage N series System-Level Diagnostics Guide for a
description of other types of tests you can run.
8. View the status of the test by entering the following command: sldiag device
status Your storage system provides the following output while the tests are
still running:
There are still test(s) being processed.
After all the tests are complete, the following response appears by default:
*> <SLDIAG:_ALL_TESTS_COMPLETED>
9. Verify that no hardware problems resulted from the addition or replacement
of hardware components on your system by entering the following command:
sldiag device status [-dev devtype] [-name device] -long -state failed
System-level diagnostics returns you to the prompt if there are no test failures,
or lists the full status of failures resulting from testing the component.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

N6240N6220N6250N6210

Table of Contents