8. Verify that no hardware problems resulted from the addition or replacement of
hardware components on your system by entering the following command:
sldiag device status [-dev devtype] [-name device] -long -state failed
System-level diagnostics returns you to the prompt if there are no test failures,
or lists the full status of failures resulting from testing the component.
9. Proceed based on the result of the preceding step.
If the system-level diagnostics tests...
Were completed without any failures
Then...
1. Clear the status logs by entering the
following command:
sldiag device clearstatus
2. Verify that the log is cleared by entering
the following command:
sldiag device status
The following default response is
displayed:
SLDIAG: No log messages are present.
3. Exit Maintenance mode by entering the
following command:
halt
4. Enter the following command at the
firmware prompt to reboot the storage
system:
boot
5. If your system is in an HA pair , enter
the cf giveback command (7-Mode) or
storage failover giveback command
(Cluster-Mode) from the partner node
console.
You have completed system-level
diagnostics.
Replacing N6200 series system devices