Replacing an interface module

You can remove an interface module and replace it with a new one while the B08S
and B16S is powered on and running.
This section provides information about the following tasks:
v General precautions
v Removing an interface module
v Installing a new interface module

Precautions

Note the following when removing and replacing interface modules:
v If you remove an interface module without first disabling it, the chassis will reboot
v You do not need to enable an interface module after inserting it in the chassis.
v You cannot mix IPv4 and IPv6 modules together in the same device.
v The software does not allow simultaneous insertion of multiple interface modules.
v If you plan to replace the removed module with a different type of module, you

Before removing an interface module

Before removing an interface module, you must have the following on hand:
v An ESD wrist strap with a plug for connection to the ESD connector on the
v A #2 Phillips-head or flathead screwdriver.
Disable the module by entering the disable module <slot-number> command at
the Privileged EXEC level of the CLI. For the <slot-number> parameter, specify a
valid slot number.
v Figure 2 on page 7 displays the slot numbers on the B08S.
v Figure 4 on page 9 displays the slot numbers on the B16S.
If you remove an interface module without first disabling it, the chassis will reboot
(reload the software).
(reload the software).
The device automatically enables the module when you insert it into a live
chassis or when you power on the chassis.
After inserting an interface module, wait a few seconds before inserting the next
module. If you attempt to insert modules one right after the other, the system will
display an error message.
must remove the module configuration. To do so, enter the no module
<slotnum> command at the global CONFIG level of the CLI. If you attempt to
insert a module of a different type without first removing the previous module
configuration, the system will display an error message.
chassis.
CAUTION:
For safety reasons, the ESD wrist strap should contain a series 1 meg ohm
resistor.
Chapter 7. Maintaining the hardware