9. Turn ON water supply.
10. Plug in dispenser.
11. Dispense 3 cups (24 oz) of water into a
container (Fig. 5). Sanitizer will fill the
dispenser water lines.
Note: Maximum length of water line between
dispenser and filter system must not exceed
30 ft. (9 m).
12. Discard water collected in container.
13. Remove the front cover and set aside.
14. Locate the ice machine electrical box
(Fig. 6.1) and press CLEAN switch
(Fig. 6.2). The MAINTENANCE light will turn
on and the machine will drain.
15. Wait for the LOW WATER light to turn on.
16. Locate the dispenser electrical box and
ensure that the BIN SIGNAL switch is ON.
17. Unplug the dispenser, wait 5 seconds and
plug back in.
18. Ice machine will resume ice making mode
(wait for MAKING ICE light to turn on) and
sanitizer will fill the ice machine water lines
and also the water reservoir.
4
Symphony Plus Pressurized Water Sanitizing Kit - No Filter
Fig. 5
Fig. 6