Adjusting the Sound Effects
Electric sound table
Function
Sound on/off
Sound on/off
Signal horn #1 (playable) 3
Signal horn #2 or bell
Fan motor (AUX 2)
Compressor
Station announcement #1 7
Coupler sound
Air outlet valve
(Line free)
Conductor whistle
Sanding valve
Close/Open doors
Brake Set / Brake Release
(automatic)
Station announcement #2 14
Curve squeal
Short whistle
Rail joints
Rail joints
52
Sound slot
CV
Range
1
259
0 – 128
2
267
0 – 128
275
0 – 128
4
283
0 – 128
5
291
0 – 128
6
299
0 – 128
307
0 – 128
8
315
0 – 128
9
323
0 – 128
10
331
0 – 128
11
339
0 – 128
12
347
0 – 128
13
355
0 – 128
363
0 – 128
15
371
0 – 128
16
379
0 – 128
17
387
0 – 128
18
395
0 – 128
19
403
0 – 128
20
411
0 – 128
21
419
0 – 128
22
427
0 – 128
23
435
0 – 128
24
443
0 – 128
Special sound table
Default
Function
99
Random sounds
99
Brake sound
Camshaft contactors (for
128
electric locos)
128
128
Before you change any of the volume control CVs, please make
sure that the CV 32 is set to 1! As explained earlier, CV 32 is used
128
as an index selection register to distinguish between the real func-
128
tion of CV 257 – 512.
128
When you adjust the volume levels, please keep in mind that you
should not exceed the maximum mixer levels to avoid a condition
128
called "clipping" which occurs when the sum of two or more sig-
nals exceeds the capacity of the output channel.
128
Clipping can be identified by clicking or popping sounds. To avoid
128
this situation, consider which sounds are likely to be played at the
128
same time and take care that their corresponding volume levels
are not set too high.
128

13.2. Prime mover startup delay

128
Usually, when the LokSound V4.0 sound is idling and you turn up
128
the throttle, the locomotives begins to move only after the Diesel
128
engine has reached notch 1. A steam loco will even release its
128
brakes first and fill the cylinders. Although this behavior is very
prototypically, one might not like it because it causes some delay.
128
You can disable this startup delay by simply deleting bit 3 of CV
128
124. This will cause the LokSound V4.0 decoder to immediately
128
start moving when the throttle is turned up. However, the start up
128
sound will not be synchon with the motion anymore.
128
128
128
Sound slot
CV
Range
-
451
0 – 128
-
459
0 – 128
-
467
0 – 128
Default
128
128
128