Environmental Specifications; Power Specifications - IBM G8052 Installation Manual

Rackswitch
Table of Contents

Advertisement

Environmental specifications

The environmental specifications for the RackSwitch G8052 are listed in the
following table.

Power specifications

The power specifications for the RackSwitch G8052 are listed in the following table.
Table 8. Environmental specifications
Specification
Temperature, ambient operating
Temperature (fan failure), operating
Temperature, storage
Relative humidity (non-condensing),
operating
Relative humidity (non-condensing), storage
Altitude, operating
Altitude, storage
Acoustic noise
Heat dissipation
Table 9. AC power specifications
Specification
Number of power supplies
AC-input frequency (universal)
AC-input voltage (universal)
AC inrush current
AC-input current (typical)
AC-input current (maximum)
Power supply rated output power
System power dissipation (typical)
System power dissipation (maximum)
DC-output current
Measurement
0° C to +40° C (32° to 104° F)
0° C to +35° C (32° to 95° F)
-40° C to +85° C (-40° to 185° F)
10 to 90%
10 to 90%
3,050 m (10,000 feet)
12,190 m (40,000 feet)
Less than 65dB
444 BTU/hour (typical)
Measurement
2 (1+1 load sharing/redundant)
50 - 60 Hz
100-240 VAC
15 A
1.1 A (RMS) @ 120 V
0.6 A (RMS) @ 230 V
1.7 A (RMS) @ 120 V
0.9 A (RMS) @ 230 V
450 W each
130 W
200 W
10.0 A (typical)
Chapter 1. Introduction