External Maintenance - Jøtul GF 300 CF Installation And Operation Instructions Manual

Conventional flue gas stove
Table of Contents

Advertisement

B
A
D
E
Figure 20. Valve Controls.
4. Push in the gas control knob (B) as far as possible and
hold it in. Simultaneously, push in the ignition knob (A)
until the spark ignites the pilot flame located to the
right rear corner of the burner..
5. Continue to hold in the gas control knob for approxi-
matelly 20 seconds after the pilot flame has been lit.
Then let go of the knob. It should pop back out and the
pilot flame should remain lit.
If the pilot flame goes out, repeat Steps 1-5.
If the pilot light goes out intentionally or unintention-
ally, it should not be relit within 3 minutes.
*NOTE: If the gas control knob does not pop out when
released, call for service.
**NOTE: If the pilot flame does not remain lit after several
attempts, turn the gas control knob to OFF and call for
service.
Lighting the Main Burner
1. Turn the gas control knob clockwise to "ON".
2. Push the ON/OFF switch at the rear of the appliance to
"ON".
NOTE: When the appliance is used for the first time,
condensation may form in the firebox. Some smoke may
also appear from the appliance during the initial hours,
due to the burning off of paint and lubrication used in
the production process. See section Odors when using the
stove for the first time.
C
Figure 21. Burner Controls.
Adjusting the Heat Setting
Heat and flame size can be adjusted by turning the regu-
lator knob (C) marked "HI, LOW", which is located next to
the gas control knob (see fig. 20). Maximum flame size
provides maximum heat. Make sure the appliance has
been operating for at least 30 minutes before adjusting
the flame.
Turning Off the Appliance
Push the ON/OFF switch at the rear of the appliance
to"OFF". The pilot flame will continue to burn. In order
to fully extinguish the appliance, push in the gas control
knob (C) (fig. 20) a little and turn clockwise to"OFF". Do
not use force.
Maintenance
The complete installation, which includes the gas sup-
ply, the actual appliance and the vent system, must be
inspected annually. The inspection must be carried out by
qualified service engineer.

External Maintenance

Painted products may change color after some years of
usage. The surface should be cleaned and brushed free
of any loose particles before new stove paint is applied.
Enameled products must only be cleaned with a soft
damp cloth and only the surface is cold.
Do not use water or soap. Enamel surfaces stain easily
when hot.
138783_Rev_2 1/2/13
13