Class 3: Filtered - for residential, commercial and light industry (Class B)
This level of performance will allow the manufacturer / assembler to self-certify compliance of their
apparatus with the EMC directive for the residential, commercial and light industrial environment as
regards the EMC performance characteristics of the power drive system. Performance limits are as
specified in the generic emission and immunity standards EN 50081-1 and EN 50082-1.
EMC Phenomenon
Emissions: (CM)
Radiated Emissions
Conducted Emissions
Immunity: (CM & MMI)
Electrostatic Discharge
Burst Interference

9.4 Environmental Aspects

Transport and Storage
Protect the COMBIMASTER/MMI against
physical shocks and vibration during
transport and storage. The unit must also
be protected against water (rainfall) and
excessive temperatures (see section 6).
The packaging is re-usable. Retain the
packaging or return it to the manufacturer
for future use.
Dismantling and Disposal
The component parts can be recycled,
disposed of in accordance with local
requirements or returned to the
manufacturer.
Documentation
This handbook is printed on chlorine-free
paper which has been produced from
managed sustainable forests. No solvents
have been used in the printing or binding
process.
74
The COMBIMASTER is intended exclusively for professional applications.
Therefore, it does not fall within the scope of the harmonics emissions specification
EN 61000-3-2.
COMBIMASTER & MICROMASTER Integrated
Standard
EN 55022
EN 55022
EN 61000-4-2
EN 61000-4-4
Siemens plc. 1999
©
REFERENCE MANUAL
Level
Level B1
Level B1
8 kV air discharge
1 kV power cables, 0.5
kV control
| G85139-H1731-U300-D2