Check that the supply voltage is
correct for the inverter used by
referring to the rating label.
Cable Glands : (Case Size A)
PG16 – Mains & Signal
Figure 3 Electrical Connection (CS A)
14
Analogue input type
Earth
Mains
connection
connection
OPm2 connector
LED
(SK200)
(green)
COMBIMASTER & MICROMASTER Integrated
Note: Jumper in 'V' position = voltage input (default)
Jumper in 'I' position = current input
JP 305
connects
PI- to 0V
I
I
JP 300
V
JP 301
V
Jumpers for
Default = V
Control cable connector
LED
(yellow)
(PL700)
IMPORTANT
Ensure that the following tightening torques are used:
Access cover retaining screws
Gland hole covers
Main connector screws
PL700 screws
Earth connection
Siemens plc. 1999
©
REFERENCE MANUAL
JP 304
connects
AIN- to 0V
JP 302
JP 303
Jumpers for
PI input type
Default = V
Control Potentiometer
(R314)
4.0 Nm
1.0 NM
1.0 Nm
0.5 Nm
1.5 Nm.