Rev 5 Apr. 13
Table 4-10: Environmental Specifications
Category
Thermal Shock
Water Resistance Test
Reliability Specifications
The LS300 has a MTBF of 10.7 years for both CDMA and HSPA versions.
MTBF calculations are performed per:
•
Telcordia "Reliability Prediction Procedure for Electronic Equipment"
document number SR-332, Issue 1
•
Method I (parts count) is used
MTBF is based on Accelerated Life Test (ALT). The ALT sequence acceleration
factor is calculated using classical reliability formulas like:
•
Arrhenius Temperature Acceleration Model
•
Peck Temperature Humidity Acceleration Model
•
Coffin–Manson Temperature Cycle Acceleration Model
•
Power Spectral Density Power Law–Vibration Acceleration Model
AirLink LS300 Specifications
Reference
MIL-STD-810, Method 501.4, 502.4
IEC 60529
37