Greasing Gas Tap; Removing Complete Fire; Spares Short List - Valor regency 328 Installation & Servicing Instructions Manual

Radiant / convector
Table of Contents

Advertisement

Valor Folium Format U/down 12/4
INSTALLATION & SERVICING INSTRUCTIONS
Replace in the reverse order. Make sure that
7.6.4.
the control knob with spindle is correctly
turned to agree with the gas tap position
before refitting the split pin.
7.7.
TO GREASE THE GAS TAP
Remove the gas tap complete with piezo
7.7.1.
generator - see section 7.5.
Remove the piezo generator as 7.6. and
7.7.2.
remove the two screws from the head of the
tap.
Remove the spindle and spring from the tap.
7.7.3.
Note the position of the slot in the plug.
7.7.4.
Mark its position on the tap body.
Rotate the plug and pull it out of the tap.
7.7.5.
Clean and grease the plug lightly with a
7.7.6.
suitable grease. Do not apply excessive
grease. Particularly, make sure that the gas
ports are not restricted by grease.
Push the plug back into the tap body. Line
7.7.7.
up the slot in the plug with the mark
previously made on the tap body.
Reassemble in the reverse order making
7.7.8.
sure that the components are correctly
engaged. Check the operation of the tap and
piezo. Make sure that the control knob with
spindle is correctly turned to agree with the
5/22/00
9:33 AM
Page 13
gas tap position before refitting the split pin.
7.8.
TO REMOVE THE COMPLETE FIRE TO CHECK
CHIMNEY FOR DEBRIS.
To gain access see section 7.2.
7.8.1.
Remove the radiants and store in a safe
7.8.2.
place.
Remove the floor plate.
7.8.3.
Undo the inlet connection at the elbow
7.8.4.
located centrally below the burner.
If wall mounted, remove the two lower fixing
7.8.5.
screws located in the back panel below the
burner then remove the two upper screws
accessible through the upper canopy grill.
Lift the fire away from the wall.
If hearth mounted, pull the fire away from
7.8.6.
the
wall.
levelling screw heads do not scratch the
hearth surface.
Remove the closure plate from the chimney
7.8.7.
opening.
Inspect the opening and clear away any
7.8.8.
debris from the base of the flue.
Reseal the closure plate and refit the fire in
7.8.9.
the reverse order.
SHORTLIST OF SPARES
figure 10
Page 13
Take
care
that
the
KEY DESCRIPTION
No. OFF
MAKER'S
PART No.
A
Gas tap
1
544609
B
Piezo generator
1
536939
C
Injector Upper Bray
cat 28 size 120
1
544619
D
Injector lower Bray
cat 28 size 250B
1
545199
E
Pilot unit
1
545949
G
Inlet elbow
1
532519
H
Control knob
1
544659
J
Radiant
3
544649
K Dress guard
1
523689
L Dust cage
1
567619

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Favourite 322Firelite 328