E. Door Handle Assembly
INSTALL NEW DOOR HANDLE
1.
Install washer on door handle shaft and slide door handle
through door.
2.
Install second washer(s) as shown and install key in groove.
3.
Align groove in latch cam with key; slide latch cam over shaft.
4.
Install locknut.
CAUTION! DO NOT OVER TIGHTEN LOCKNUT. DOOR
HANDLE NEEDS TO MOVE SMOOTHLY.
5.
Install fiber hand using a clockwise motion until the fiber handle
is snug against the door handle shaft.
F. Outside Air Kit Installation
A source of air (oxygen) is necessary in order for combus-
tion to take place. Whatever combustion air is consumed
by the fire must be replaced. Air is replaced via air leakage
around windows and under doors. In homes that have tightly
sealed doors and windows, an outside air source is needed.
An optional Outside Air Kit is available.
Optional OAK-ACC includes:
flex adapter, and fasteners
Items Needed for Installation (not supplied)
• 4 inch flex aluminum pipe, or if using alternate material,
then it shall be made from durable, non-combustible,
heat resistant material up to 350
required length for your installation.
• Phillips head screw driver
• Silicone sealant
• Drills and saws necessary for cutting holes through the
wall or flooring in your home.
Installation Instructions
1. Remove all materials from packing box.
Floor & Rear Installation: Cut a 4 inch (102mm) hole in
2.
outside wall or floor to accommodate outside air piping.
Use 4 inch (102mm) aluminum metal flex or rigid piping
to directly connect outside air to appliance intake. Use
the supplied termination cap with a rodent screen. Seal
between the wall (or floor) and the pipe with silicone to
prevent moisture penetration.
September 27, 2016
Figure 21.1
Termination cap, (2) wire ties,
o
F. Cut the pipe to the
WARNING
Asphyxiation Risk.
Length of outside air supply duct shall NOT exceed the
length of the vertical height of the exhaust flue.
• Fire will not burn properly
• Smoke spillage occurs when door is opened due to air star-
vation
For Floor Installa-
tions Remove
Circular "Knock-Out"
in Base of Pedestal.
Flex Line
Figure 21.2
Fire Risk. Asphyxiation Risk.
Do not draw outside combustion air from:
Wall, floor or ceiling cavity
Enclosed space such as an attic or garage
Close proximity to exhaust vents or chimneys
Fumes or odor may result
Asphyxiation Risk.
Outside air inlet must be located to prevent blockage
from:
• Leaves
• Snow or ice
Block may cause combustion air starvation
Smoke spillage may set off alarms or irritate sensitive individuals.
7038-206F
5700 STEP TOP ACC
Flex Adapter
Wire Tie
Termination
Cap
Wire Tie
WARNING
WARNING
• Other debris
21