NOTE: A heat loss calculation should be performed to
properly determine the required furnace BTU size for the
structure. Also, the duct must be properly designed and in-
stalled for proper airflow. Existing ductwork must be in-
spected for proper size and to make sure that it is properly
sealed. Proper airflow is necessary for both user comfort
and equipment performance.
Before opening the furnace carton, verify that the data
tags on the carton specify the furnace model number
that was ordered from the distributor and are correct
for the installation. If not, return the unit without open-
ing the carton. If the model number is correct, open
the carton and verify that the furnace rating label
specifies the same furnace model number that is
specified on the carton label. If the model numbers do
not match, return the furnace to the distributor.
IMPORTANT: Proper application, installation and mainte-
nance of this furnace and system is a must if consumers
are to receive the full benefits for which they have paid.
The (-)96V and (-)(-)96MDV series furnaces are design-
certified by CSA for use with natural and propane gases as
follows:
FIGURE 1
FURNACE COMPONENTS
11
7
8
23
9
6
5
1
2
4
3
22
10
14
24
12

GENERAL INFORMATION

1. As non-direct vent central forced air furnaces taking
combustion air from the installation area or using air
ducted from the outside.
2. As direct vent central forced air furnaces with all com-
bustion air supplied directly to the furnace burners
through a special air intake system outlined in these
instructions.Install this furnace in accordance with the
American National Standard Z223.1 – latest edition
entitled "National Fuel Gas Code" (NFPA54) or, for
Canada, CSA B149.1; Canadian Natural Gas and
Propane Installation Code and requirements or codes
of the local utilities or other authorities having jurisdic-
tion. This is available from the following:
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA 02269
CSA-INTERNATIONAL
5060 Spectrum Way
Mississauga, Ontario
Canada L4W5N6
Online: www.csa.ca
13
16
ITEM
NO.
1
2
3
15
4
5
6
17
7
8
9
10
11
5
12
13
14
15
16
17
18
18
19
20
19
21
22
23
21
24
20
25
DESCRIPTION
CONDENSATE TRAP
DOOR SWITCH
JUNCTION BOX
TRANSFORMER
WATER SENSOR (2)
PRESSURE SWITCHES,
HIGH & LOW STAGE
EXHAUST TRANSITION
COUPLING (ELBOW TO TRANSITION)
EXHAUST
SHIPPING PLUG
FLAME SENSOR
OVER TEMPERATURE SWITCH
TOP PLATE
BURNER
IGNITER
COMBUSTION AIR INLET
GAS VALVE
INDUCED DRAFT BLOWER (IDB)
POWER FACTOR CORRECTION CHOKE
(PFC) ( EXCEPT 56KBTU AND 70KBTU)
CONTROL MOUNTING PLATE
BLOWER
LOW VOLTAGE TERMINAL
COUPLING (IDB TO ELBOW)
FURNACE CONTROL
ST-A1205-01
3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

96mdv series

Table of Contents