THERMOSTAT WIRING DIAGRAMS
FIGURE 56
WIRING DIAGRAM FOR A LEGACY 2-STAGE THERMOSTAT.
ST-A1194-62-01
19. 24VAC AND COMMON CONNECTIONS (E10/E11)
For connection to the low voltage side of the control
transformer. Terminals are ¼" quick-connect style.
20. FUSE (P100/P101)
A fuse is provided to protect low-voltage (24VAC) cir-
cuits from shorts between 24VAC and Ground or
102
HEAT PUMPS
ONLY
Common. A fault code 30 is displayed at the furnace
control when the fuse has been opened.
On the next page is a timing diagram for normal heat se-
quence. This diagram assumes no faults are present dur-
ing the heat call.