NOTE: A heat loss calculation should be performed to
properly determine the required furnace BTU size for the
structure. Also, the duct must be properly designed and in-
stalled for proper airflow. Existing ductwork must be in-
spected for proper size and to make sure that it is properly
sealed. Proper airflow is necessary for both user comfort
and equipment performance.
Before opening the furnace carton, verify that the data
tags on the carton specify the furnace model number
that was ordered from the distributor and are correct
for the installation. If not, return the unit without open-
ing the carton. If the model number is correct, open
the carton and verify that the furnace rating label
specifies the same furnace model number that is
specified on the carton label. If the model numbers do
not match, return the furnace to the distributor.
IMPORTANT: Proper application, installation and mainte-
nance of this furnace and system is a must if consumers
are to receive the full benefits for which they have paid.
The (-)97V series furnaces are design-certified by CSA for
use with natural and propane gases as follows:
FIGURE 1
FURNACE COMPONENTS
11
7
8
24
9
6A
23
5
26
1
2
4
3
22

GENERAL INFORMATION

10
15
12
13
1. As non-direct vent central forced air furnaces taking
combustion air from the installation area or using air
ducted from the outside.
2. As direct vent central forced air furnaces with all com-
bustion air supplied directly to the furnace burners
through a special air intake system outlined in these
instructions.Install this furnace in accordance with the
American National Standard Z223.1 – latest edition
entitled "National Fuel Gas Code" (NFPA54) or, for
Canada, CSA B149.1; Canadian Natural Gas and
Propane Installation Code and requirements or codes
of the local utilities or other authorities having jurisdic-
tion. This is available from the following:
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA 02269
CSA-INTERNATIONAL
5060 Spectrum Way
Mississauga, Ontario
Canada L4W5N6
Online: www.csa.ca
14
16
ITEM
NO.
DESCRIPTION
17
1.
CONDENSATE TRAP
2.
DOOR SWITCH
3.
JUNCTION BOX
4.
TRANSFORMER
5.
WATER SENSOR (2)
6B
6.
PRESSURE SWITCH STAGES
A. HIGH
6C
B. MEDIUM
C. LOW
7.
EXHAUST TRANSITION
8.
COUPLING (ELBOW TO TRANSITION)
9.
EXHAUST
5
10.
SHIPPING PLUG
11.
FLAME SENSOR
18
12.
OVER TEMPERATURE SWITCH
13.
TOP PLATE
19
14.
BURNER
15.
IGNITER
16.
COMBUSTION AIR INLET
20
17.
GAS VALVE
18.
INDUCED DRAFT BLOWER (IDB)
19.
POWER FACTOR CORRECTION CHOKE
(PFC) (NOT USED ON THE 60K BTU
21
AND 70K BTU)
20.
CONTROL MOUNTING PLATE
21.
BLOWER
22.
LOW VOLTAGE TERMINAL
23.
COUPLING (IDB TO ELBOW)
24.
MAIN LIMIT
25.
FURNACE CONTROL
26.
AUXILIARY TRAP
25
ST-A1194-67-00
3

Advertisement

Table of Contents
loading

Table of Contents