Upflow With Vertical Vent - Rheem 96v series Installation Instructions Manual

4 position condensing two-stage, communicating gas furnaces w/ecm blower
Table of Contents

Advertisement

UPFLOW VERTICAL VENT
PARTS NEEDED:
!
PARTS NEEDED FOR THIS CONVERSION REQUIRE ITEMS
FROM THE PARTS BAG ONLY. NO OTHER CONVERSION
KITS ARE NEEDED.
FROM PARTS BAG (PROVIDED WITH UNIT)
HOSE
CLAMP
(X2)
TOOLS/MATERIALS NEEDED:
ELECTRIC DRILL
1/4" HEX HEAD DRIVER
NOTE: THESE CONVERSION INSTRUCTIONS ARE INTENTIONALLY GENERIC, SOME PARTS MAY BE DIFFERENT IN YOUR FURNACE
2
OPTION DRAIN LEFT
DRILL 1/8"
7/8" PLUG
DISCARD
DETERMINE RIGHT OR LEFT DRAIN OPTION.
LOCATE 7/8" HOLE IN JACKET SIDE.
REMOVE PLUG - DISCARD.
DRILL (2) Ø 1/8" HOLES FOR THE CONDENSATE DRAIN COUPLING.
4A
4a - LEFT SIDE DRAIN OPTION
ATTACH HOSE A (PRE-INSTALLED) TO CONDENSATE DRAIN
COUPLING. INSTALL HOSE CLAMP ON HOSE OVER CONDENSATE
DRAIN COUPLING.
NOTE:
USE SOAPY WATER TO FACILITATE EASY
HOSE AND TUBE ASSEMBLY
TUBE C
CONDENSATE
DRAIN
#8 X 1/2"
COUPLING
COUPLING
SCREW
(X2)
PLIERS
1/8" DRILL BIT
TUBE CUTTER
OPTION DRAIN RIGHT
4B
HOSE A
4b - RIGHT SIDE DRAIN OPTION
4b1 - CUT TUBE C TO FIT CORRESPONDING CABINET WIDTH.
4b2 - INSTALL TUBE C WITH HOSE CLAMP AS SHOWN TO HOSE A (PRE-INSTALLED).
4b3 - ATTACH TUBE C ASSEMBLY TO CONDENSATE DRAIN COUPLING AS SHOWN.
4b4 - INSTALL HOSE CLAMP OVER HOSE ON CONDENSATE DRAIN COUPLING.
NOTE:
USE SOAPY WATER TO FACILITATE EASY
HOSE AND TUBE ASSEMBLY
1
INTAKE
W/ NUT
INSTALL INTAKE COUPLING IN TOP PLATE.
3
7/8" PLUG
DISCARD
DRILL 1/8"
INSTALL CONDENSATE DRAIN COUPLING USING (2)
SCREWS. INSTALL IN JACKET WITH THE BARBED FITTING
POINTED INTO THE VESTIBULE.
TUBE C
CUT TO FIT
CABINET WIDTH
4b1
4b2
(X2)
HOSE A
INSTALL
INSTALL
4b4
4b3
TUBE C
ST-A1194-28-X0
15