Summary of Contents for Perfect Aire 1PAMSH09-SZW-14.5
Page 1
COMFORT...BUILT TO LAST 9,000, 12,000 and 18,000 BTU SINGLE-ZONE DUCTLESS MINI-SPLIT SYSTEM Heat Pump INSTALLATION MANUAL INDOOR UNIT: 1PAMSH09-SZW-14.5 1PAMSH09-SZW-15 1PAMSH12-SZW-15 1PAMSH18-SZW-15 OUTDOOR UNIT: 1PAMSH09-SZO-14.5 1PAMSH09-SZO-15 1PAMSH12-SZO-15 1PAMSH18-SZO-15 Before using your air conditioner, please read this manual carefully and keep it for future...
Contents This manual provides the information needed for proper use and maintenance of this air conditioner. Basic preventative care can help extend the life of this unit. The “Troubleshooting Tips” section in this manual contains a chart with solutions to the most common problems. Referring to this section may save time and prevent the need for a service call in the event of a problem.
Safety Precautions INSTALLATION PRECAUTIONS • Read this installation manual carefully before operating the unit to ensure correct installation. • Installation must be performed in accordance with the requirement of NEC and CEC by a trained service technician only. • Contact a trained service technician for repair, maintenance and installation of this unit. •...
Installation Instructions Selecting an installation location Please read through the following directions completely before installing. When installing, follow these step by step. Indoor Unit Fig. 1 • Do not expose the indoor unit to heat or steam. ≥ 6 in. •...
Installation Instructions (cont.) Settling of Outdoor Unit • The outdoor unit should be installed on a concrete or plastic pad or mounted to Fig. 2 a wall with the proper brackets and secured per local and national codes. • NOTE: The outdoor unit you purchase may be like one of the following. Install the outdoor unit according to the applicable unit using the dimensions the table below.
Installation Instructions (cont.) Indoor Unit Installation 1. Install the Installation Plate Fig. 5 Indoor unit outline 6 in. or more to ceiling • Fit the installation plate horizontally on structural parts of the wall with space around the installation plate. 4.8 in.
Installation Instructions (cont.) 3. Connect the cable to the Indoor unit Electrical Work Electric safety regulations for the initial installation: • If there are any safety concerns with the electrical power supply, the technician should consult a certified electrician and have the problem resolved before installing the unit. •...
Installation Instructions (cont.) 4. Connective Pipe and Drainage Installation Fig. 8 Drainage • Run the drain hose sloping downward. Do not install the drain hose as illustrated in the "wrong" figures in Figure 8. • When connecting extension drain hose, insulate the connecting part of extension drain hose with a shield pipe.
Installation Instructions (cont.) Outdoor Unit Installation IMPORTANT: See pages 3 – 4 of this manual for instructions regarding the outdoor unit's installation location. 1. Outdoor Unit Installation Precautions • Install the outdoor unit on a rigid base to prevent increased noise level and vibration. •...
Air Purging and Test Operation 4. Connect the Cable to the Outdoor Unit • Remove the electrical control board cover from the outdoor unit by loosening the screw. • Attach the electrical whip from the outdoor disconnect to the proper connections shown in the wiring diagram. •...
Air Purging and Test Operation (cont.) When Using the Vacuum Pump • Completely tighten the flare nuts (A, B, C, D). Connect the manifold valve charge hose to a charge port of the packed valve on the gas pipe side. •...