2-3 Installation

Installing the Sensor
FQ2-S@@@@@@ (Sensors with Built-in Lighting)
Installation Procedure
1
Align the tabs on one side of the Mounting Bracket with
the slot on the Sensor.
The FQ-XL Mounting Bracket can be attached to the back,
side, or front of the Sensor.
2
Press the Mounting Bracket onto the Sensor until the oth-
er tabs click into place.
3
Use the following optical charts to check the field of view
and installation distance of the Sensor so that it is mount-
ed at the correct position.
Tightening torque (M4): 1.2 N·m
Horizontal field of view
Installation distance (L)
FQ2-S@@010F, FQ2-@@010F
Installation distance (L) (mm)
55
45
35
6
8
10
Horizontal field of view (mm)
FQ2-S@@050F, FQ2-S@@050F
Installation distance (L) (mm)
210
130
50
0
20
Horizontal field of view (mm)
FQ2 User's Manual
The optical chart indicates the horizontal
field of view. The vertical field of view
Vertical field
depends on the model as follows:
of view
FQ2-S@@@@@@:
Approx. 60% of the horizontal field of view
FQ2-S@@@@@@-08@:
Approx. 90% of the horizontal field of view
Note: The tolerance is ±10%.
Installation distance (L) (mm)
12
14
Installation distance (L) (mm)
40
60
FQ2-S@@100F, FQ2-S@@100F
1,000
600
200
0
100
200
Horizontal field of view (mm)
FQ2-S@@100N, FQ2-S@@100N
400
0
0
200
Horizontal field of view (mm)
Mounting
Bracket
300
400
33
Installation