Register Description - SeaLevel PLC-16.PCI User Manual

Hide thumbs Also See for PLC-16.PCI:
Table of Contents

Advertisement

Register Description

All ports are set to input after reset or power up.
Address Mode
Base+0
Base+1
Base+2
Base+3
Base+4
Base+5
Base+6
Base+7
Interrupt Control
When enabled, interrupts are generated on Port A bit D0.
IRQEN
IRC0
IRC1
Interrupt Mode Select Table
Interrupt source is Base+0 bit D0. When selecting the Interrupt Type, always disable
interrupts prior to changing or setting states. This will help prevent inadvertent or
unexpected interrupts from occurring.
Warning: When using the High and Low Level interrupts, an interrupt occurs when
input D0 changes to either a High or Low state. This will cause the computer to
remain in an interrupt state until the input state changes.
© Sealevel Systems, Inc.
D7
D6
RD/WR PAD7
PAD6
RD
{0}
{0}
RD/WR PCD7
PCD6
RD
{0}
{0}
RD
{0}
{0}
RD/WR IRQEN IRQST {0}
RD
{0}
{0}
RD
{0}
{0}
Interrupt enable
IRC1
IRC0
Interrupt Type
0
0
0
1
High Level
1
0
Falling Edge
1
1
Rising Edge
D5
D4
D3
PAD5 PAD4 PAD3 PAD2 PAD1 PAD0
{0}
{0}
{0}
PCD5 PCD4 PCD3 PCD2 PCD1 PCD0
{0}
{0}
{0}
{0}
{0}
{0}
{0}
{0}
{0}
{0}
{0}
{0}
{0}
{0}
1 = enabled
Interrupt mode select, see table below
Interrupt mode select, see table below
Low Level
- 13 -
D2
D1
D0
{0}
{0}
{0}
{0}
{0}
{0}
{0}
{0}
{0}
{0}
IRC1
IRC0
{0}
{0}
{0}
{0}
{0}
{0}
0 = disabled ( 0 on power up )