Overview Of Electrical Connections For External And Internal Actuators; Installation; Opening The Units; To Open The Outdoor Unit - Daikin ERLQ004CA Installer's Reference Manual

Altherma - low temperature split
Hide thumbs Also See for ERLQ004CA:
Table of Contents

Advertisement

6.4.4 Overview of electrical connections for
external and internal actuators
The following illustration shows the required field wiring.
INFORMATION
The following illustration is an example and may NOT
match your system layout.
c
20
12
6
15
b
13
14
17
18
8 10
9 19
a
a Single power supply for outdoor unit, backup heater and
booster heater
b Backup heater
c Indoor unit
d Domestic hot water tank
e Booster heater
Item
Description
Outdoor unit and indoor unit power supply
1
Power supply for
outdoor unit
2
Power supply and
interconnection cable
to indoor unit
3
Power supply for
backup heater
4
Preferential kWh rate
power supply (voltage
free contact)
5
Normal kWh rate power
supply
User interface
6
User interface
Optional equipment
7
3-way valve
8
Power supply for
booster heater and
thermal protection
(from indoor unit)
9
Power supply for
booster heater (to
indoor unit)
10
Domestic hot water
tank thermistor
11
Power supply for
bottom plate heater
12
Room thermostat
13
Outdoor ambient
temperature sensor
14
Indoor ambient
temperature sensor
15
Heat pump convector
Field supplied components
EHBH04+08 + ERLQ004~008

Daikin Altherma - Low Temperature Split

4P313774-1 – 2012.05
7
M
21
16
M
14
d
e
Maximum
running
Wires
current
2+GND or
(a)
3+GND
3
(c)
See table below. —
2
(e)
2
6.3 A
2
(f)
3
100 mA
4+GND
(c)
2+GND
13 A
2
(d)
2
(b)
3 or 4
100 mA
2
(b)
2
(b)
4
100 mA
Item
16
Shut-off valve
17
Electricity meter
18
Domestic hot water
pump
19
Alarm output
20
Changeover to external
heat source control
21
Space cool/heat
operation control
22
Power consumption
digital inputs
(a) Refer to name plate on outdoor unit.
(b) Minimum cable section 0.75 mm².
(c) Cable section 2.5 mm².
(d) The thermistor and connection wire (12 m) are delivered with the
(e) Cable section 0.75 mm² till 1.25 mm²; maximum length: 50 m.
(f) Cable section 0.75 mm² till 1.25 mm²; maximum length: 500 m.
Backup heater
type
*3V
*9W
7

Installation

7.1

Opening the units

7.1.1 To open the outdoor unit

1
Remove 1 screw from the service cover.
(b)
2
Remove the service cover.
(b)
(b)
Description
Wires
2
2 (per meter)
2
2
2
2
2 (per input
signal)
domestic hot water tank.
Voltage-free contact shall ensure the minimum applicable load of
15 V DC, 10 mA.
Applicable for both single user interface and dual use interface
connection.
Required number of
Power supply
1x 230 V
2+GND
1x 230 V
2+GND + 2 bridges
3x 230 V
3+GND + 1 bridge
3x 400 V
4+GND
2
1x
1
2
7 Installation
Maximum
running
current
(b)
(b)
(b)
(b)
(b)
(b)
(b)
conductors
Installer reference guide
26

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ehbh08caErlq008caEhbx04caEhbx08caEhbh04caErlq006ca