Installation manual Daikin Altherma - Low Temperature Split EHBH04CA EHBH08CA EHBH16CA EHBX04CA Installation manual EHBX08CA English Daikin Altherma - Low Temperature Split EHBX16CA...
Page 2
CE - FÖRSÄKRAN-OM-ÖVERENSTÄMMELSE CE - DECLARAŢIE-DE-CONFORMITATE CE - UYUMLULUK-BİLDİRİSİ Daikin Europe N.V. declares under its sole responsibility that the equipment to which this declaration relates: заявляет, исключительно под свою ответственность, что оборудование, к которому относится настоящее заявление: deklaruje na własną i wyłączną odpowiedzialność, że urządzenia, których ta deklaracja dotyczy: erklärt auf seine alleinige Verantwortung daß...
To connect the power consumption digital inputs ..Latest revisions of the supplied documentation may be available on Finishing the indoor unit installation .......... 12 the regional Daikin website or via your dealer. 3.6.1 To fix the user interface cover to the indoor unit ..
Sound plate (only for EHBH/X16) l Screws for fixing sound plate (only for EHBH/X16) 4 Remove the accessories k+l (only for EHBH/X16). These accessories are located at the bottom of the packaging. Installation manual EHBH/X04~16CA Daikin Altherma - Low Temperature Split 4P313771-1C – 2012.11...
6 Hook the unit against the wall. To install, see the installation manual of the drain pan kit. EHBH/X04~16CA Installation manual Daikin Altherma - Low Temperature Split 4P313771-1C – 2012.11...
7 Disconnect the water supply hose from the drain and fill valve. 3.4.3 To fill the domestic hot water tank For installation instructions, see the installation manual of the domestic hot water tank. Installation manual EHBH/X04~16CA Daikin Altherma - Low Temperature Split 4P313771-1C – 2012.11...
For *3V models, use a single pole fuse for F1B. For *9W c Preferential power supply contact models, use a double pole fuse for F1B. 2 Fix the cable with cable ties to the cable tie mountings. Installation manual EHBH/X04~16CA Daikin Altherma - Low Temperature Split 4P313771-1C – 2012.11...
1 Connect the valve control cable to the appropriate terminals as shown in the illustration below. From the rear NOTICE Wiring is different for a NC (normal closed) valve and a NO (normal open) valve. Installation manual EHBH/X04~16CA Daikin Altherma - Low Temperature Split 4P313771-1C – 2012.11...
1 Connect the alarm output cable to the appropriate terminals as shown in the illustration below. 1 Connect the power consumption digital inputs cable to the appropriate terminals as shown in the illustration below. EHBH/X04~16CA Installation manual Daikin Altherma - Low Temperature Split 4P313771-1C – 2012.11...
3 If you do NOT press any button for more than 1 hour or press again for more than 4 seconds, the user permission level switches back to End user. Installation manual EHBH/X04~16CA Daikin Altherma - Low Temperature Split 4P313771-1C – 2012.11...
Code Description start/stop cycles of the heat pump and more economic operation. [6.3.2] Number that users can call in case of problems. EHBH/X04~16CA Installation manual Daikin Altherma - Low Temperature Split 4P313771-1C – 2012.11...
Pwr consumpt. control Mode Type Amp. value [A.7] Commissioning kW value Test run Amp. limits for DI kW limits for DI UFH screed dryout Air purge Priority Actuator test run Installation manual EHBH/X04~16CA Daikin Altherma - Low Temperature Split 4P313771-1C – 2012.11...
3 Select Start air purge and press and press 4 Select OK and press Result: The air purge starts. It stops automatically when done. To stop it manually, press , select OK and press EHBH/X04~16CA Installation manual Daikin Altherma - Low Temperature Split 4P313771-1C – 2012.11...
▪ Show the user what jobs he/she has to do in relation to maintenance of the unit. ▪ Explain the user about energy saving tips as described in the operation manual. Installation manual EHBH/X04~16CA Daikin Altherma - Low Temperature Split 4P313771-1C – 2012.11...
* : optional On/OFF thermostat (wired) (*) : standard for *HV*, optional for *HB* On/OFF thermostat (wireless) # : field supply Ext. thermistor Heat pump convector 4D077028 page 1 EHBH/X04~16CA Installation manual Daikin Altherma - Low Temperature Split 4P313771-1C – 2012.11...
Page 20
Only for demand PCB option only for EKBPHT* only if no EKBPHT* Options: bottom plate heater OR On/OFF output Only for digital I/O PCB option 4D077028 page 3 Installation manual EHBH/X04~16CA Daikin Altherma - Low Temperature Split 4P313771-1C – 2012.11...
Page 21
Safety contactor backup heater (only for *9W) * = Optional Relay on PCB (*) = Standard for EHVH/X, optional for EHBH/X Main supply pump # = Field supply Domestic hot water pump Black EHBH/X04~16CA Installation manual Daikin Altherma - Low Temperature Split 4P313771-1C – 2012.11...
In case user interface is relocated 2x0.75 X5M: 1-2 A2P: P1-P2 user interface communication OPTIONAL PART Only for *KRCAL* 2 core 2x0.75 communication A2P: P1-P2 user interface 4D078494 EHBH/X04~16CA Installation manual Daikin Altherma - Low Temperature Split 4P313771-1C – 2012.11...
Page 24
6 / 9 configuration Regular kWh rate power supply Electrical 3~ balanced meter type 3~ unbalanced Benefit kWh rate power supply Electrical 3~ balanced meter type 3~ unbalanced 4D078288 Installation manual EHBH/X04~16CA Daikin Altherma - Low Temperature Split 4P313771-1C – 2012.11...