To Connect The Shut-Off Valve; Daikin Altherma - Low Temperature Split - Daikin ERLQ004CA Installer's Reference Manual

Altherma - low temperature split
Hide thumbs Also See for ERLQ004CA:
Table of Contents

Advertisement

7 Installation
From the rear
PCB
1x
b
a Notch this part for the wiring to pass through with nippers
etc.
b Secure the wiring to the front part of the casing using the
wiring retainer and clamp.
5
Reinstall the faceplate onto the wallplate.
NOTICE
Be careful NOT to pinch the wiring when attaching the
frontplate to the unit.
Fixation of the user interface to the wall in case of installation as
room thermostat
1
Insert a screwdriver into the slots underneath the user interface
and carefully separate the faceplate from the wallplate.
NOTICE
The PCB is mounted in the faceplate of the user interface.
Be careful NOT to damage it.
2
Fix the wallplate of the user interface to wall.
3
Connect the wires to the user interface as shown below.
From the rear
PCB
1x
b
From the left
PCB
1x
a
b
Installer reference guide
39
a
a
From the top
a
b
PCB
1x
b
From the top center
b
PCB
1x
b
a Notch this part for the wiring to pass through with nippers
etc.
b Secure the wiring to the front part of the casing using the
wiring retainer and clamp.
4
Reinstall the faceplate onto the wallplate.

7.6.7 To connect the shut-off valve

1
Connect the valve control cable to the appropriate terminals as
shown in the illustration below.
NOTICE
Wiring is different for a NC (normal closed) valve and a NO
(normal open) valve.
NO
6 7
5
X2M
X1M
M2S
2
Fix the cable with cable ties to the cable tie mountings.
a
NC
5
7
6
X2M
X1M
M2S
EHBH04+08 + ERLQ004~008

Daikin Altherma - Low Temperature Split

4P313774-1 – 2012.05

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ehbh08caErlq008caEhbx04caEhbx08caEhbh04caErlq006ca